Hase Lagos User Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
37
13. Technical Data
TheLagos,certiedincompliancewithDIN-EN 13240 : 2001 + A2 2004 and Art.
15 a B-VG(Austria),canonlybeoperatedwhenthereboxisclosed;morethan
onedevicecanbeconnectedtothechimney.VKF-No.:22403;
ThefollowingdataappliestothechimneycharacteristicsinaccordancewithEN
13384-1/2:
Dependingontheinsulationofthebuilding,thenominalthermaloutputof5 kW
indicatedon15 - 60 m²(subjecttochange).
Dimensions: Height Width Depth
Stove 140cm 48,5cm 53,5cm
Firebox 39cm 31cm 41cm
Weightwithoutheatretainingblock
(steel/ceramic/soapst.): 151/188/195 kg
Heatretainingblock(optional): 78 kg
Fluepipediameter: 15 cm
PipediameterofHaseventilationsystem* 10 cm
*Forseparateairsupplyinlow-energyhousesandinsufcientcombustionairsupplyinthe
roomwherethestoveisinstalled
Combustion Values Wood Briquettes
NominalThermalOutput 5 5 kW
WasteGasMassFlowRate 5,0 5,0 g/s
WasteGasOutletTemp. 300 300 ˚C
Min.SupplyPressureatNominalThermalOutput 12 12 Pa
COcontentat13%O2 1217 844 mg/m³
Efciency 81 82 %
Particulate < 10 < 20 mg/m³
Dimensionsincm
Frontview
Sideview
Stoveheight:140
Topview
Heightforrearinstallation:128,5
Heightfortopinstallation:112
min. 33
48,5
42,5
21
53,5
Heightfortheinst.ofHaseairsystem:8,5
48,5
Ø 31
5,5
Connection area for the inst.
of Hase air system below
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 45 46

Comments to this Manuals

No comments